Centre Testing International Group Co., Ltd. (NG28) is a market leader in testing, inspection, certification, calibration, audit, training & technical services; building trust between governments, enterprises, and consumers.
Sustainability is deeply rooted in NG28’s business model, by delivering science-based solutions and verification services, to increase transparency and traceability throughout the global value chain. NG28 is a proponent of carbon neutrality and sustainable development.
Centre Testing International Co., Ltd. (NG28) is the pioneer and leader in the TIC Industry which provides one-stop solutions on testing, inspection, certification, calibration, audit, training & technical services.
Our service capabilties cover the upstream and downstream of the supply chain including textile and apparel,toys,electronic appliances,medical health,food...andother industries.
Our service capabilties cover the upstream and downstream of the supply chain including textile and apparel,toys,electronic appliances,medical health,food...andother industries.
Comprehensively guarantee quality and safety, promote compliance and innovation, demonstrate brand competitiveness, and achieve higher quality, healthier, safer, and greener sustainable development.
We have established a clear governance structure in accordance with listing requirements and national regulations and policies to deal with internal and external challenges and achieve sustainable development.
Ensuring the basic rights and benefits of employees;
Providing professional skills training to promote employees’ growth;
Carrying out various kinds of activities to balance employees’ work and life.
The rapid development of domestic economy is inseparable from the security guarantee of the power system. In the power system the demand for wires and cables is also increasing. All kinds of inferior wire and cable products flooded the whole market and seriously affected our engineering and personal safety. NG28 can test the raw materials, finished products and accessories of wires and cables. This test can ensure the safety of products and provide support for product improvement and quality improvement.
? Business Challenges
How is the quality safety of wires and cables tested?
How is the quality of wires and cables verified?
? Service content
Ⅰ. Applicable Test Standards
GB/T 2099 Plugs and socket-outlets for household and similar purposes
GB/T 2951 Common test methods for insulating and sheathing materials of electric and optical cables
GB/T 3956 Conductors of insulated cables
GB/T 5013 Rubber insulated cables of rated voltages up to and including 450/750 V
GB/T 5023 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
GB/T 9330.1 Plastic insulated control cables. Part 1: General requirements
GB/T 12706.1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2 kV) up to 35 kV (Um=40.5 kV) ). Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
GB/T 16915.1 Switches for household and similar fixed-electrical installations. Part 1: General requirements
GB/T 19666 General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables
GB/T 25085/ISO 6722 Road vehicles. 60V and 600V single-core cables
JB/T 8139 Road vehicles-low voltage cables (wires)
JB/T 8734.1 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V. Part 1: General requirements
JB/T 8735.1 Rubber insulated cords and flexible cables of rated voltages up to and including 450/750 V. Part 1: General requirements
JB/T 10491.1 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V. Part 1:General requirements
QB/T 1453 Cable supports system
JB/T 10216 Cable support system for electric control distribution
T/CECS 31 Technical specification for steel cable supporting system engineering, etc.
Ⅱ. Product Range
Electrical engineering, Automobile, Rail transit, Electrical equipment, Communication, Construction, etc.
Ⅲ. Standard Sample Requirements
Please contact our business or customer service, based on specific standards.
Ⅳ. Test Item
Main test items |
|
Low temperature winding |
Impact at low temperature |
Abrasion test |
Test for vertical flame propagation for a single insulated wire or cable |
Cold impact |
Temperature Rise |
Measurement of thickness and overall dimensions |
Resistance to ageing, protection provided by enclosures of switches and resistance to moisture |
Electrical resistance of conductors/voltage test carried out on completed cables |
Creepage distances, clearances and distances through sealing compound |
Insulation resistance and electric strength |
Resistance of insulating material to abnormal heat, to fire and tracking |
Pressure test at high temperature |
Ozone aging |
Test method for determining mechanical and physical properties of electric cables and wires |
Degrees of protection(IP code) |
? NG28 Solution
NG28 provides a comprehensive one-stop solution of reliability testing, including:
Environmental test
Reliability test
Reliability design
Reliability analysis
Product evaluation
Reliability training and consulting
? Our Strengths
NG28 has many advanced equipments and has passed CMA/CNAS qualification accreditation, the test data is accurate and reliable, and the test report has international credibility.
The scientific laboratory information management system ensures the efficient operation of each service link.
The technical expert team has rich practical experience and can provide professional, rapid and comprehensive one-stop service.
The service network is all over the world, and many first-line brands designate cooperative laboratories.
? Service Process
Consult customer service → confirm the test plan → fill in the application form → send the sample → pay the test fee → test → send electronic report → express paper report
? Q&A
How long does the test period take?
The normal period is 5-7 working days (except the time when the sample is in the test chamber). If you need urgent help, please contact our sales or customer service.
What are the sample requirements for the low temperature winding test of the cable?
The diameter of the low temperature winding test cable shall not exceed 10 mm. Before testing it is needed to confirm the diameter of the sample to be tested and the required load.
What are the sample requirements for the cold impact test of the cable?
The diameter of cables for cold impact test shall be range 4mm to 75mm.
Before testing it is needed to confirm the diameter of the sample to be tested and the required weight of drop hammer.
How is the result of pressure test at high temperature for wires and cables evaluated?
The pressure, temperature and heating time on the blade should be confirmed before pressure test at high temperature for wires and cables. The evaluation is based on taking the maximum intermediate value for the indentation depth of the tested sample.